MCDYLAN

Products

Air source heat pumps
designed for severe winter conditions.

From 8 kW domestic units to commercial modular units, from 55°C hot water to 85°C high temperature, selected for the building, climate and heat demand profile rather than sold by model number.

Heating at −30°CR410A refrigerantFull DC inverterSingle or three phase

Domestic heating and cooling

Combined heating and cooling for villas and self-built homes

The Lanfeng and Chifeng series combine air conditioning and underfloor heating in one unit: radiant floor heating in winter, fan coil cooling in summer, and stable heating even at −30°C. Suited to villas, self-built homes, guesthouses and small commercial spaces.

Request selection and quote

Lanfeng series ultra-low-temperature full DC inverter heating and cooling monobloc

DXL8/12/15/18ID · 220V — Homes, villas and guesthouses of 80–200 m², with underfloor heating, fan coils or radiators.

Chifeng series single-phase monobloc

Single-phase 220V — Township self-built homes and small commercial spaces without three-phase power.

Chifeng series three-phase monobloc

Three-phase 380V — Larger homes, small hotels and offices where the load is better balanced.

Ultra-low-temperature full DC inverter split unit

Split type — Separate outdoor and indoor units for retrofits and spaces with limited room.

Commercial heating and cooling

Central heating and cooling for hotels, schools and campuses

Modular commercial units run in parallel to match the load and stay efficient at part load. Central control and remote monitoring suit hotels, schools, hospitals, offices and mixed-use developments.

Request selection and quote

Ultra-low-temperature commercial inverter air source heat pump

−30°C operation — Winter heating and summer cooling for hotels, schools and hospitals in northern China.

Low-temperature commercial air source heat pump

−20°C operation — Standard heating and cooling projects in north and northwest China.

Commercial air source heat pump

Standard conditions — Heating, cooling and hot water projects in east, central and south China.

Ultra-low-temperature full DC inverter split unit

Split type — Retrofit projects with restricted roof loading or a need for distributed placement.

Commercial hot water

Constant-temperature hot water for hotels, bathhouses and dormitories

Circulating units size tanks and heat pumps to the peak-and-off-peak water curve and deliver 55–85°C outlet water. Multiple units can run in parallel for high volume, continuous supply and year-round operation.

Request selection and quote

Standard commercial circulating hot water unit

55–60°C — Hotels, dormitories, pools and bathhouses in southern China.

Low-temperature commercial circulating hot water unit

−20°C operation — Winter hot water in northern China, with insulated storage tanks and a return system.

Low-temperature cascade 85°C high-temperature hot water unit

Up to 85°C — Electroplating, printing and dyeing, slaughtering, food processing and industrial cleaning.

System components

Terminals, tanks and controls

A heat pump is a system, not a single machine. We supply underfloor heating, fan coils, tanks, pumps and control systems per project, reducing disputes between parties.

Request selection and quote

Underfloor heating and fan coil terminals

Configured to drawings — Radiant floor heating and fan coil air distribution, matched to room loads.

Insulated storage tanks and pressure vessels

Sized to water volume — Capacity determined by peak water demand and simultaneous use rate.

Smart control and remote monitoring

Optional — Multi-unit coordination, scheduling and fault alarms for unmanned plant rooms.

Technical specifications

Lanfeng series DXL 8–18ID

The figures below cover the published 220V/1PH/50Hz models. Ask your regional manager for the full selection table, low-temperature performance curves and noise data.

ModelRated heating (7/6°C)Nominal heating (−12/−14°C)Rated cooling (35/24°C)Heating COPIPLV(H)
DXL8ID9.0 kW6.5 kW7.5 kW3.443.0
DXL12ID13.0 kW10.5 kW11.0 kW3.37—
DXL15ID17.0 kW12.0 kW15.0 kW3.44—
DXL18ID21.0 kW15.0 kW18.0 kW3.39—

Figures are nominal laboratory data. Actual performance varies with ambient temperature, water temperature and installation conditions; the technical manual and nameplate supplied with each unit take precedence.

Selection guidance

Calculate the load first, then choose the model.

Two buildings of the same area can differ by more than 30% in load depending on insulation, ceiling height, orientation and terminal type. These are the five variables most often overlooked.

Lanfeng series ultra-low-temperature air source heat pumpDXL 8 / 12 / 15 / 18 ID
  • Building heat load — Calculate from the building envelope, window-to-wall ratio, ceiling height and design indoor temperature. Do not guess in “watts per square metre”.
  • Outdoor design temperature — Check against the local mean temperature of the coldest month over the last 30 years and the extreme temperature; a −30°C unit does not deliver full output in every condition.
  • Terminal type — Underfloor heating works at low water temperature with high comfort; fan coils respond quickly; radiators need higher water temperature, which directly affects model choice.
  • Simultaneous use rate — Hotels, dormitories and bathhouses differ widely in peak simultaneous demand, which determines tank volume and the number of units.
  • Installation and defrost — Unit spacing, orientation, drainage and defrost water handling determine real winter output and noise.